Monday, April 1, 2019
Thermal Solutions to Reduce Electricity Costs
caloric Solutions to Reduce Electricity CostsExecutive summaryThis report investigates and analyses the caloric solutions to reduce the electricity comprise for senior drill at St Aidans Angli tush Girls School. Approaches of analysis include calculating capacity loss, thermic flowing and comparing authoritative follows and rewrite costs, as well as the long ( apiece term and annual) prediction for function consumption. The annual electricity cost is predicted to be $23064.56. All calculations can be found in the Appendix. Results from compute information show that 29.09% of the strength consumption can be trim by replacing 36 W lights from 18 W organ pipe light bulbs ($4.90 for devil tubes, $44.10 overall) and installing the Hampton caloric mantels ($276 in total) with pelmet boxes ($183) of tail fin years life expectancy. Hence, they are suggested to renovate any cinque years to maintain the efficiency of caloric curtains. Although these installations leav e behind need $503.10 initially, the payback will begin from the 7th month.This report evaluates that the current setting of the classroom in senior school can be altered to protect the env compresss and derogate electricity costs. Therefore, there are most recommendationsInstall the Hampton caloric curtains with pelmet boxesThermal curtains should be shut all the time in order to achieve the revised costSmall engineering devices (e.g. projector, printer, iron and zealous glue guns) impost should be understated to reduce power utilisation (e.g. turn them off sort of of stand-by when non using)There are some weaknesses of the reportThermal current of furniture in the room is not considered.Monthly temperature data are not exact results, they are base on past average temperature data.Number of classrooms are an approximation instead of counting due to variation in classroom setting (e.g. atomic number 53 air-conditi starr, more or less lights, fridge)Key assumptionsThe p ower is assumed to be use only on schooldays.The energy loss from the recorded data (the energy required to cool down) is assumed to be the same every day.The room is assumed to be a closed system, so the thermal current of windows is identical to the power usage of both air-conditionings.Power consumption AnalysisIntroductionThermal (heat) energy always tends to transfer from one hot space spreading to colder surroundings space by conduction, convection and radiation sickness (Cambridge University Press, 2014) and its flow is affected by the temperature difference. Thermal current () is the rate at which heat energy passes through a material, which is calculated as . The thermal conductivity (k) is a measure of how well the material transfers heat rase values of conductivity indicate better insulating material. Thermal insulators such as thermal curtains and double glazing windows are commonly utilize in homes or buildings to maintain constant room temperature by prevention of convection current and minimise energy usage. This report will investigate, analyse and recommend thermal solutions for the school to reduce electricity usage and environmental benefits.Investigation and discussion railway line All data refers to Appendix CalculationThe data was collected by using Sparkvue temperature sensors connected to a computer. The first 30 minutes of the data was disregarded due to the sensor being exposed to direct sunlight, leading to the extremely high temperature (especially the summit at 319pm at 47.4C) at the beginning of the data (Graph 1). Through analysis and calculations of the data, the internal temperature change had a positive gradient (between 504pm and 604pm) which indicated the room was gaining energy as the air-conditioning turned off (347.08 W).Current power usageDuring schooldays, 18 lights were used 1 hour 43 minutes per day and two air-conditionings were used 10 hours daily on average. The lights were found to consume a relatively l ow amount of energy of 1.11 kWh daily. Since the room was assumed to be a closed system, theoretically, the thermal current of the windows (137.14 kWh) should be equivalent to the power usage of air-conditioners. However, due to the information written on the air-conditioning was its upper most power usage, they would not be equal. In fact, the calculated consumption (Table 2) was less than the presumption data, which indicated the difference in power usage could be attributed to dissipation through the walls, floors and doors openings. Moreover, the total consumption (139.52 kWh) included the power consumption of lights and technology devices in the room to achieve higher accuracy.Thermal solutionsThermal solutions are bonny and beneficial to diminish power consumption. The 36 W light bulbs can be replaced by 18 W lights, which each consume 0.56 kWh daily. Furthermore, thermal curtains are the most common thermal products, because more internal thermal convection current will be blocked, especially when the curtains are extended so that it reaches the floor. This would prevent the convection current and reduce energy flow into the room (Figure 9). picture and triple glazing of windows are commonly used as well, due to hoover between glass panes eliminating losses by conduction and convection however, installation is expensive, so thermal curtains are the most economic thermodynamic barriers to use in order to reduce the energy usage. Figure 9 No geological fault (Rogers A, 2011)From researching thermal curtains, the Hampton thermal curtain is thermal coated which reduces a maximum of 25% energy loss (Energy.GOV, 2012). Only the front windows pick up connectedness with direct sunlight others are all under shelter, so thermal curtains will only cover these. Hence, the Hampton thermal curtain is suggested to be installed for energy reduction, costing $276 in total. Pelmet boxes cost $183 overall, because the side of the front windows have a length of 6. 02 m each, it would be liable to get two 6.10 m pelmet box on each side(some space for the curtain rod). The life expectancy of thermal curtains is usually five years it is reasonable for the school to renovate new curtains every five years. It can be seen from Graph 2 that the costs maintain the same and extends by another(prenominal) full cost of $503.1 after renovating at the end of each five year cycle. Furthermore, the power usage with thermal solutions is calculated to be 97.25 kWh, having a 29.09% difference compared with the current settings.CBA Cost Benefit AnalysisThe CBA graph (Graph 3) shows the current cost model and revised cost model accumulating over time. The break-even insinuate occurs in the 7th month and when the current cost is approximately equivalent to the revised cost at $1661.8 and $1654.3, the current cost will trump the revised cost. According to the CPI in Queensland has been fluctuating from 2007 to 2012 (Figure 10), which may ride out changing in the next few years. By considering a long-term situation, Graph 4 illustrates an example of revised cost will increase every five years due to renovation of curtains, whilst maintaining a littler rate of power consumption than the current cost. The power consumption for each term is calculated (Table 3-6) and used to investigate the annual revised cost of $23064.56 and 28.98% of electricity cost will be reduced from current cost in the senior school. If the electricity price increases 5% for both peak and off-peak hours, the trend would stay the same as the current cost has a higher gradient than the revised cost (Graph 4) and the fluctuation has an impact on the overall costs. (Australian Government, 2015)Figure 10 CPI Annual Change BrisbaneRecommendationsThe net goal of diminishing the energy usage is to protect our environment and minimise energy consumption.ThereforeThermal curtains with pelmet boxes and light bulbs should be installed.Curtains should be shut all the time in order to achieve the revised cost.It would be the most economical way if all small technology devices are not used at all (e.g. projector, printer, iron and hot glue guns).In conclusion, after installing the thermal solutions it is predicted to spend $23064.56 per year in the senior school, and results in saving approximately $13072 on power usage when all assumptions are valid, which will therefore reduce environment impact.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.